LMA200 Microwave Moisture Analyzer
Brand : Sartorius
Moisture meter LMA200 for the moisture analysis in liquid and pasty samples with a moisture content ranging from approx. 8 to 100 %. The humidity meter uses microwave drying which produces results up to 300 x faster than a drying oven for samples with high moisture content. A built-in analytical weighing system inside the moisture meter LMA200 measures the weight loss of a sample and determines the end point at which the sample has reached a constant weight.
Description
If the sample contains a high moisture content, microwave drying is the fastest and most effective procedure (loss-on-drying) for heating samples. A sample is heated by absorption of microwave radiation. A built-in analytical weighing system measures the weight loss of a sample and determines the end point at which the sample has reached a constant weight. In addition, an air moisture sensor monitors the progress of a moisture analysis run, thus providing double the certainty to assure reliable results.
- Can be used for liquid and pasty samples with a moisture content ranging from approx. 8 to 100%
- Analysis time approx. 40 - 120 seconds (depends on type of sample and moisture content)
- Easy two-key operation for routine moisture measurements
- End-point determination: Fully automatic, by means of mass and moisture sensors; User-defined as loss of weight/unit of
- time for measurement; Timer mode
- Built-in analytical weighing system with a capacity of 70 g and a resolution of 0.1 mg for weight values
Specification
Product properties
Weighing Range |
70 g
|
Heating source |
Microwave radiation, for ultra short measuring times
|
Number of measuring programs |
300
|
Application |
Very moist samples, fluid or pasty
|
Recommended moisture range |
8 - 100%
|
Line voltage |
115 V
|
Readability |
0,1 mg, 0,001 %
|
Technical attributes
Line voltage |
230 V
|
Max. weighing capacity |
70g
|
Accuracy of the weighing system |
0.0001g
|
Reproducibility (Repeatability) on average for initial sample weights of 1 g or higher (%) |
+/- 0.05
|
Type of sample carrier |
Glass fiber pads, diameter 90mm (3.5")
|
Display mode for results |
% moisture, ppm moisture, % volatile components, % dry weight (solids), ppm dry weight, g dry weight, mg weight loss, % RATIO
|
Temperature range and settings |
Approx. 8 - 100 % moisture
|
Heating unit (choice of) |
Microwave generator with 1000 W input power
|
Power control for heating |
2-100%, adjustable in 1% increments
|
End-point determination |
Fully automatic,by means of mass and moisture sensors; User-defined as loss of weight/unit of time: 1-50 mg / 1-99 sec., 0.1-9.9% / 1-99 sec.; Timer mode: 0.1 - 99.9 min.
|
Analysis time |
Approx. 40-120 (depends on type of sample and moisture content)
|
Programs |
Saved in the non-volatile memory
|
Data Printer |
Thermal printer,built-in
|
Moisture measurement report |
User-configured GLP report; The report can be printed on non-fading paper by the built-in thermal printer
|
Operator guidance |
Menu-driven, alphanumeric dialogue text (english, french, german, italian and spanish selectable); 5 pre-programed function keys
|
Data interface |
1x RS232 port for PC; 1x Ethernet port
|
Line frequency |
50 Hertz
|
Width |
510 x 535 x 304 mm
|
Weight |
22 kg
|
Max. power consumption |
1200 VA
|